 Analytical Facilities - Mass Spectrometry Section

  Gas Chromatography Mass Spectrometry: Graham Calder


  RRI homepage
> Analytical Facilities > Mass Spectrometry > Gas Chromatography Mass Spectrometry

Gary_Calder

Graham Calder

Facilities support research in:

• Protein Metabolism

• Structural Analysis

• Quantitative Analysis by Isotope Dilution

The section has 4 gas chromatography mass spectrometers (GC/MS). These instruments are mainly used to quantitate compounds of biological interest by isotope dilution and to measure the enrichment in deuterium, carbon-13 or nitrogen-15 in target metabolites in relation to kinetic studies using stable isotopes as tracers. These metabolites are isolated from biological fluids using chromatography techniques prior to derivatisation and GC/MS analysis. The instruments have the ability to operate in two modes of ionisation. Chemical ionisation (CI) and electron impact ionisation (EI). CI is a soft ionisation technique which is used to enhance the molecular ion, this is a very sensitive technique requiring only small quantities (pg) of material. Electron impact ionisation (EI) requires more material (ng) but looks at unique fragments derived from each metabolite. Using EI allows the isotopic labelling in different atoms of the molecule to be defined (isotopomer analysis) and thus can support more complex metabolic studies utilising multiple tracers.

Instruments available:

Agilent 5973 MSD

Agilent 5973 MSD

• 6890N Gas Chromatograph
• 7683 Auto sampler
• Electron impact (EI)
• Positive and Negative Chemical Ionization (CI)
• Isotopes measured: - 13-C , 15-N, 2-H

HP 5989A MS 'Engine' Quadrupole Mass Spectrometer

HP_5989A_MS_Engine

• HP 5890 Series II Gas Chromatograph
• HP 7673 Auto sampler
• Electron impact (EI)
• Positive and Negative Chemical Ionization (CI)
• Isotopes measured: - 13-C , 15-N, 2-H

Thermoquest Trio-1 Quadrupole Mass Spectrometer

Thermoquest_Trio-1

• HP 5890 Series II Gas Chromatograph
• HP 7673 Auto sampler
• Electron impact (EI) Ionization only
• Isotopes measured: - 13-C , 15-N, 2-H

Thermoquest 'Voyager' Quadrupole Mass Spectrometer

• GC 8000 Top Gas Chromatograph
• AS 800 Auto sampler
• Electron impact (EI)
• Positive and Negative Chemical Ionization (CI)
• Isotopes measured: - 13-C , 15-N, 2-H

 

• Contact Mass Spectrometry Section (Analytical Facilities Staff list)